Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
1.
Pol Arch Intern Med ; 134(4)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38483121

RESUMEN

INTRODUCTION: Transfemoral access is a prevailing approach for transcatheter aortic valve implantation (TAVI) in contemporary practice, with a shift from surgical arteriotomy to a percutaneous arterial approach. OBJECTIVES: This study assessed long- and short­term mortality, along with Valve Academic Research Consortium-2-defined complications in percutaneous transfemoral approach (PTA) TAVI. Furthermore, it explored the impact of a learning curve on procedural outcomes. PATIENTS AND METHODS: The study included 600 patients undergoing PTA TAVI at the National Institute of Cardiology, Warsaw, Poland, from January 2009 to September 2020. Retrospective data comparison involved 2 groups: early experience (first 200 patients) and late experience (next 400 patients). RESULTS: The primary end point (composite of life­threatening bleeding, major vascular complication, or death at 30 days) occurred less often in the late experience group (28% vs 17.5%; P = 0.003). The late experience group also showed fewer cases of vascular complications (19% vs 10.7%; P = 0.005) and major bleeding (17.5% vs 8.5%; P = 0.001). Propensity matching yielded similar trends, including reduced frequency of pacemaker implantation (22.8% vs 10.9%; P = 0.03) and shorter median (interquartile range) hospitalization (11 [8-18] vs 7 [6-12] days; P <0.001) in the late experience group. CONCLUSIONS: The late experience group rated with PTA TAVI exhibited significantly reduced periprocedural complications, indicating a positive impact of accumulated expertise.


Asunto(s)
Estenosis de la Válvula Aórtica , Arteria Femoral , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Femenino , Masculino , Anciano , Anciano de 80 o más Años , Estudios Retrospectivos , Polonia , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento
2.
Am J Cardiol ; 217: 25-28, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38432337

RESUMEN

What is the efficacy and safety of transcatheter tricuspid valve-in-valve implantation for patients with inoperable tricuspid surgical prosthesis dysfunction? Thirty-day mortality after greatly effective transcatheter treatment is 2 times less than the estimated surgical risk.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Falla de Prótesis , Válvula Tricúspide/cirugía , Resultado del Tratamiento , Cateterismo Cardíaco , Diseño de Prótesis , Insuficiencia Cardíaca/cirugía
5.
Arch Med Sci ; 19(6): 1781-1794, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38058732

RESUMEN

Introduction: In the following study we describe the diagnostic process and further case analysis of a 30-year-old woman admitted with typical COVID-19 symptoms, who subsequently developed additional symptoms suggesting cerebral autosomal dominant arteriopathy with sub-cortical infarcts and leukoencephalopathy (CADASIL). Material and methods: Other than the standard diagnostic procedures, whole genome sequencing (WGS) was used, which led to following findings. A new variant of the NOTCH3 gene, which led to CADASIL-like symptoms, was found, and it had been most likely activated by the SARS-CoV-2 infection. This novel variant in NOTCH3 has not been found in existing databases and has never been mentioned in research concerning CADASIL before. Results: Furthermore, after subjecting the patient's close relatives to WGS it was found that no other examined person demonstrated the same genetic mutation. Conclusions: It seems therefore that the new variant of NOTCH3 is of de novo origin in the patient's genome. Additionally, the relatively early onset of CADASIL and the unexpectedly severe COVID-19 infection suggest that the two occurred simultaneously: the infection with SARS-CoV-2 accelerated development of CADASIL symptoms and the unusual variant of the NOTCH3 gene contributed to the more severe course of COVID-19.

6.
Postepy Kardiol Interwencyjnej ; 19(3): 251-256, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37854972

RESUMEN

Introduction: Data regarding patients with a previous medical record of immunosuppression treatment who have undergone transcatheter aortic valve implantation (TAVI) are limited and extremely inconclusive. Available studies are mostly short term observations; thus there is a lack of evidence on efficacy and safety of TAVI in this specific group of patients. Aim: To compare the in-hospital and long-term outcomes between patients with or without a medical history of immunosuppressive treatment undergoing TAVI for aortic valve stenosis (AS). Material and methods: We conducted a retrospective registry-based analysis including patients undergoing TAVI for AS at 5 centres between January 2009 and August 2017. The primary endpoint was long-term all-cause mortality. Secondary endpoints comprised major vascular complications, life-threatening or disabling bleeding, stroke and new pacemaker implantation. Results: Of 1451 consecutive patients who underwent TAVI, two propensity-matched groups including 25 patients with a history of immunosuppression and 75 patients without it were analysed. No differences between groups in all-cause mortality were found in a median follow-up time of 2.7 years following TAVI (p = 0.465; HR = 0.73; 95% CI: 0.30-1.77). The rate of major vascular complications (4.0% vs. 5.3%) was similar in the two groups (p = 1.000). There were no statistically significant differences in the composite endpoint combining life-threatening or disabling bleeding, major vascular complications, stroke and new pacemaker implantation (40.0% vs. 20.0%, p = 0.218). Conclusions: Patients who had undergone TAVI for AS had similar long-term mortality regardless of whether they had a previous medical record of immunosuppression. Procedural complication rates were comparable between the groups.

8.
Postepy Kardiol Interwencyjnej ; 19(1): 40-46, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37090206

RESUMEN

Introduction: One of the crucial aspects of transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) is the valve prosthesis selection. Aim: To assess the consistency of the aortic valve sizing in SAVR and TAVR by comparing the sizes of aortic prostheses selected based on the intraprocedural annulus measurements and simulation of the TAVR planning. Material and methods: The study comprised of 167 patients with aortic stenosis treated with SAVR. Simulation of the prosthesis sizing blinded to the SAVR results was performed based on the assessment of cardiac computed tomography (CCT) images. Results: Based on the CCT images, the average value of the aortic annulus diameter was 25.4 ±3.0 mm. Aortic valve calcifications were mild in 29 cases, moderate in 78 cases, and severe in 53 cases. The sizes of the valves recommended by the simulations were larger than valves surgically implanted in 98.6% of patients for self-expanding and in 91.7% of patients for balloon-expandable prostheses. The average difference for self-expanding prostheses was 6.4 mm and 4.5 mm for balloon expandable valves. Additionally, a negative correlation was observed for the difference in prosthesis size and size of the valve used by surgeons. Conclusions: There is a systematic difference between sizes of aortic prostheses used in SAVR and TAVR. Further studies are needed to evaluate if the difference in prosthesis size selection contributes to the frequency of prosthesis-patient mismatch phenomenon and burden of high postoperative mean transaortic gradient.

9.
J Clin Med ; 12(5)2023 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-36902604

RESUMEN

BACKGROUND: The two most common organisms found in infective endocarditis following transcatheter aortic valve implantation (TAVI-IE) are enterococci (EC-IE) and staphylococci (SC-IE). We aimed to compare clinical characteristics and outcomes of patients with EC-IE and SC-IE. METHODS: TAVI-IE patients from 2007 to 2021 were included in this analysis. The 1-year mortality was the primary outcome measure of this retrospective multi-center analysis. RESULTS: Out of 163 patients, 53 (32.5%) EC-IE and 69 (42.3%) SC-IE patients were included. Subjects were comparable with regard to age, sex, and clinically relevant baseline comorbidities. Symptoms at admission were not significantly different between groups, except for a lower risk for presenting with septic shock in EC-IE than SC-IE. Treatment was performed in 78% by antibiotics alone and in 22% of patients by surgery and antibiotics, with no significant differences between groups. The rate of any complication, in particular heart failure, renal failure, and septic shock during treatment for IE, was lower in EC-IE compared with SC-IE (p < 0.05). In-hospital (EC-IE: 36% vs. SC-IE: 56%, p = 0.035) and 1-year mortality (EC-IE: 51% vs. SC-IE: 70%, p = 0.009) were significantly lower in EC-IE compared with SC-IE. CONCLUSIONS: EC-IE, compared with SC-IE, was associated with a lower morbidity and mortality. However, absolute numbers are high, a finding that should trigger further research in appropriate perioperative antibiotic management and improvement of early IE diagnosis in the case of clinical suspicion.

10.
Front Oncol ; 13: 1045817, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36845707

RESUMEN

Introduction: Population-based cancer screening has raised many controversies in recent years, not only regarding the costs but also regarding the ethical nature and issues related to variant interpretation. Nowadays, genetic cancer screening standards are different in every country and usually encompass only individuals with a personal or family history of relevant cancer. Methods: Here we performed a broad genetic screening for cancer-related rare germline variants on population data from the Thousand Polish Genomes database based on 1076 Polish unrelated individuals that underwent whole genome sequencing (WGS). Results: We identified 19 551 rare variants in 806 genes related to oncological diseases, among them 89% have been located in non-coding regions. The combined BRCA1/BRCA2 pathogenic/likely pathogenic according to ClinVar allele frequency in the unselected population of 1076 Poles was 0.42%, corresponding to nine carriers. Discussion: Altogether, on the population level, we found especially problematic the assessment of the pathogenicity of variants and the relation of ACMG guidelines to the population frequency. Some of the variants may be overinterpreted as disease-causing due to their rarity or lack of annotation in the databases. On the other hand, some relevant variants may have been overseen given that there is little pooled population whole genome data on oncology. Before population WGS screening will become a standard, further studies are needed to assess the frequency of the variants suspected to be pathogenic on the population level and with reporting of likely benign variants.

11.
Eur Heart J Qual Care Clin Outcomes ; 9(8): 768-777, 2023 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-36637410

RESUMEN

AIMS: Prediction of adverse events in mid-term follow-up after transcatheter aortic valve implantation (TAVI) is challenging. We sought to develop and validate a machine learning model for prediction of 1-year all-cause mortality in patients who underwent TAVI and were discharged following the index procedure. METHODS AND RESULTS: The model was developed on data of patients who underwent TAVI at a high-volume centre between January 2013 and March 2019. Machine learning by extreme gradient boosting was trained and tested with repeated 10-fold hold-out testing using 34 pre- and 25 peri-procedural clinical variables. External validation was performed on unseen data from two other independent high-volume TAVI centres. Six hundred four patients (43% men, 81 ± 5 years old, EuroSCORE II 4.8 [3.0-6.3]%) in the derivation and 823 patients (46% men, 82 ± 5 years old, EuroSCORE II 4.7 [2.9-6.0]%) in the validation cohort underwent TAVI and were discharged home following the index procedure. Over the 12 months of follow-up, 68 (11%) and 95 (12%) subjects died in the derivation and validation cohorts, respectively. In external validation, the machine learning model had an area under the receiver-operator curve of 0.82 (0.78-0.87) for prediction of 1-year all-cause mortality following hospital discharge after TAVI, which was superior to pre- and peri-procedural clinical variables including age 0.52 (0.46-0.59) and the EuroSCORE II 0.57 (0.51-0.64), P < 0.001 for a difference. CONCLUSION: Machine learning based on readily available clinical data allows accurate prediction of 1-year all-cause mortality following a successful TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Lactante , Anciano , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía
12.
Int J Mol Sci ; 23(15)2022 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-35955824

RESUMEN

Background: Severe outcomes of COVID-19 account for up to 15% of all cases. The study aims to check if any gene variants related to cardiovascular (CVD) and pulmonary diseases (PD) are correlated with a severe outcome of COVID-19 in a Polish cohort of COVID-19 patients. Methods: In this study, a subset of 747 samples from unrelated individuals collected across Poland in 2020 and 2021 was used and whole-genome sequencing was performed. Results: The GWAS analysis of SNPs and short indels located in genes related to CVD identified one variant significant in COVID-19 severe outcome in the HADHA gene, while for the PD gene panel, we found two significant variants in the DRC1 gene. In this study, both potentially protective and risk variants were identified, of which variants in the HADHA gene deserve the most attention. Conclusions: This is the first study reporting the association between the HADHA and DRC1 genetic variants and COVID-19 severe outcome based on the cohort WGS analysis. Although all the identified variants are localised in introns, they may be correlated and therefore inherited along with other risk variants, potentially causative to severe outcome of COVID-19 but not discovered yet.


Asunto(s)
COVID-19 , Enfermedades Cardiovasculares , COVID-19/genética , Enfermedades Cardiovasculares/genética , Estudio de Asociación del Genoma Completo , Humanos , Mutación INDEL , Pulmón , Polimorfismo de Nucleótido Simple
13.
Front Cardiovasc Med ; 9: 931207, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35966561

RESUMEN

Background: A severe prosthesis-patient mismatch (PPM) is associated with adverse outcomes following transcatheter aortic valve replacement (TAVR) for de novo aortic stenosis or a failed surgical bioprosthesis. The impact of severe PPM in patients undergoing TAV-in-TAVR is unknown. Aim: We sought to investigate the incidence and 1-year outcomes of different grades of PPM in patients undergoing TAV-in-TAVR. Materials and methods: The TRANSIT-PPM is an international registry, including cases of degenerated TAVR treated with a second TAVR. PPM severity, as well as in-hospital, 30-day, and 1-year outcomes were defined according to the Valve Academic Research Consortium-3 (VARC-3) criteria. Results: Among 28 centers, 155 patients were included. Severe PPM was found in 6.5% of patients, whereas moderate PPM was found in 14.2% of patients. The rate of severe PPM was higher in patients who underwent TAV-in-TAVR with a second supra-annular self-expanding (S-SE) TAVR (10%, p = 0.04). Specifically, the rate of severe PPM was significantly higher among cases of a SE TAVR implanted into a balloon-expandable (BE) device (19%, p = 0.003). At 1-year follow-up, the rate of all-cause mortality, and the rate of patients in the New York Heart Association (NYHA) class III/IV were significantly higher in the cohort of patients with severe PPM (p = 0.016 and p = 0.0001, respectively). Almost all the patients with a severe PPM after the first TAVR had a failed < 23 mm BE transcatheter heart valve (THV): the treatment with an S-SE resolved the severe PPM in the majority of the cases. Conclusion: After TAV-in-TAVR, in a fifth of the cases, a moderate or severe PPM occurred. A severe PPM is associated with an increased 1-year all-cause mortality. Clinical trial registration: [https://clinicaltrials.gov], identifier [NCT04500964].

14.
Kardiol Pol ; 80(10): 1020-1026, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35892248

RESUMEN

BACKGROUND: An increase in pulmonary artery diameter (PAD) on multi-detector computed tomography (MDCT) may indicate pulmonary hypertension. We assessed the prognostic value of MDCT-derived measurements of PAD on outcomes after successful transcatheter aortic valve replacement (TAVR). METHODS: Consecutive patients treated with TAVR from February 2013 to October 2017, with a 68.8% rate of new generation valves, underwent pre-interventional MDCT with measurements of PAD (in the widest short-axis within 3 cm of the bifurcation) and ascending aortic diameter (AoD; at the level of the PAD). The PAD/AoD ratio was calculated. Patients with high-density lipoprotein cholesterol levels ≤46 mg/dl and C-reactive protein levels ≥0.20 mg/dl at baseline were identified as the frail group. One-year mortality was established for all subjects. RESULTS: Among studied 266 patients (median age, 82.0 years; 63.5% women) those who died at 1 year (n = 34; 12.8%) had larger PAD and PAD/AoD (28.9 [5.0] vs. 26.5 [4.6] mm and 0.81 [0.13] vs. 0.76 [0.13] mm vs. the rest of the studied subjects; P = 0.005 and P = 0.02, respectively) but similar AoD. The cutoff value for the PAD to predict 1-year mortality was 29.3 mm (sensitivity, 50%; specificity, 77%; area under the curve, 0.65). Patients with PAD >29.3 mm (n = 72; 27%) had higher 1-year mortality (23.6% vs. 8.8%, log-rank P = 0.001). Baseline characteristics associated with PAD29.3 mm were a bigger body mass index, more frequent diabetes mellitus, more prior stroke/transient ischemic attacks and atrial fibrillation, and lower baseline maximal aortic valve gradient with higher pulmonary artery systolic pressure (PASP). PAD >29.3 mm and frailty, but not baseline PASP, remained predictive of 1-year mortality in the multivariable model (hazard ratio [HR], 2.221; 95%CI, 1.038-4.753; P = 0.04 and HR, 2.801; 95% CI, 1.328-5.910; P = 0.007, respectively). CONCLUSION: PAD >29.3 mm on baseline MDCT is associated with higher 1-year mortality after TAVR, independently of echocardiographic measures of PH and frailty.


Asunto(s)
Estenosis de la Válvula Aórtica , Fragilidad , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Fragilidad/complicaciones , Fragilidad/cirugía , Tomografía Computarizada Multidetector , Pronóstico , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía , Factores de Riesgo , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
15.
Front Cardiovasc Med ; 9: 894497, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35800165

RESUMEN

Objectives: Patients with bicuspid aortic valve (BAV) stenosis were excluded from the pivotal trials of transcatheter aortic valve implantation (TAVI). We compared the in-hospital and long-term outcomes between patients undergoing TAVI for bicuspid and tricuspid aortic valve (TAV) stenosis. Methods: We performed a retrospective registry-based analysis on patients who underwent TAVI for BAV and TAV at five different centers between January 2009 and August 2017. The primary outcome was long-term all-cause mortality. Secondary outcomes were in-hospital mortality, procedural complications, and valve performance. Results: Of 1,451 consecutive patients who underwent TAVI, two propensity-matched cohorts consisting of 130 patients with BAV and 390 patients with TAV were analyzed. All-cause mortality was comparable in both groups up to 10 years following TAVI (HR 1.09, 95% CI: 0.77-1.51). Device success and in-hospital mortality were comparable between the groups (96 vs. 95%, p = 0.554 and 2.3 vs. 2.1%, p = 0.863, respectively). Incidence of procedural complications was similar in both groups, with a trend toward a higher rate of stroke in patients with BAV (5 vs. 2%, p = 0.078). Incidence of moderate or severe paravalvular leak (PVL) at discharge was comparable in both groups (2 vs. 2%, p = 0.846). Among patients with BAV, all-cause mortality was similar in self-expanding and balloon-expandable prostheses (HR 1.02, 95% CI: 0.52-1.99) and lower in new-generation devices compared to old-generation valves (HR 0.27, 95% CI 0.12-0.62). Conclusion: Patients who had undergone TAVI for BAV had comparable mortality to patients with TAV up to 10 years after the procedure. The device success, in-hospital mortality, procedural complications, and PVL rate were comparable between the groups. The high rate of neurological complications (5%) in patients with BAV warrants further investigation.

16.
Kardiol Pol ; 80(7-8): 792-798, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35521716

RESUMEN

BACKGROUND: Aortic stenosis (AS) is the most common valvular heart disease and untreated has a bleak prognosis. The only effective method of treatment is valve replacement, surgical (SAVR), or transcatheter (TAVI). AIMS: We decided to analyze outcomes and predictors of long-term mortality in patients undergoing TAVI and SAVR. METHODS: A retrospective analysis of 1229 patients with advanced AS, comprising TAVI (n = 211), SAVR (n = 556), SAVR, and additional procedures (n = 462), operated on from 2014 to 2018, was performed. RESULTS: No significant differences between SAVR and TAVI were found for 24-month mortality in groups of consecutive patients. Postoperative stroke or transient ischemic attack (TIA), chronic obstructive pulmonary disease (COPD), and transfusion of red blood cells (RBCs) were independent predictors of 1-year mortality after SAVR. The above-mentioned factors regarding the increased estimated surgery risk in the EuroSCORE II ( > 4%) were predictors of 2-years mortality after SAVR. Risk factors for 6- and 12-month mortality after TAVI were EuroSCORE II, new onset of atrial fibrillation (NOAF), and the increased RBC distribution width (RDW). Postoperative respiratory failure was an independent risk factor for 6-, 12- and 24-month mortality in both groups of patients. CONCLUSIONS: There were no significant differences regarding prognosis after TAVI and SAVR at the 24-month follow-up in the propensity score matching model. Independent predictive factors of late mortality after both procedures were EuroScore II and respiratory failure. Independent predictive factors of late mortality specific for TAVI were NOAF, increased RDW, and for SAVR: TIA, stroke, COPD, and RBC transfusion.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Ataque Isquémico Transitorio , Enfermedad Pulmonar Obstructiva Crónica , Insuficiencia Respiratoria , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Constricción Patológica/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Ataque Isquémico Transitorio/etiología , Ataque Isquémico Transitorio/cirugía , Insuficiencia Respiratoria/etiología , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
17.
Int J Mol Sci ; 23(9)2022 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-35562925

RESUMEN

Although Slavic populations account for over 4.5% of world inhabitants, no centralised, open-source reference database of genetic variation of any Slavic population exists to date. Such data are crucial for clinical genetics, biomedical research, as well as archeological and historical studies. The Polish population, which is homogenous and sedentary in its nature but influenced by many migrations of the past, is unique and could serve as a genetic reference for the Slavic nations. In this study, we analysed whole genomes of 1222 Poles to identify and genotype a wide spectrum of genomic variation, such as small and structural variants, runs of homozygosity, mitochondrial haplogroups, and de novo variants. Common variant analyses showed that the Polish cohort is highly homogenous and shares ancestry with other European populations. In rare variant analyses, we identified 32 autosomal-recessive genes with significantly different frequencies of pathogenic alleles in the Polish population as compared to the non-Finish Europeans, including C2, TGM5, NUP93, C19orf12, and PROP1. The allele frequencies for small and structural variants, calculated for 1076 unrelated individuals, are released publicly as The Thousand Polish Genomes database, and will contribute to the worldwide genomic resources available to researchers and clinicians.


Asunto(s)
Genética de Población , Genoma Humano , Alelos , Frecuencia de los Genes , Humanos , Proteínas Mitocondriales , Polonia
18.
J Clin Med ; 11(6)2022 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-35329959

RESUMEN

Background: In patients with HCM at high risk of SCD, an ICD should be considered as a standard of care. Current risk approximation algorithms recommended by ESC 2014 criteria indicate that SCD risk is not stable. The aim of the study was to investigate how the calculated SCD risk in HCM patients with an ICD implanted in the past changed over time. Methods: We analyzed 64 HCM patients with ICD for primary prevention, referred for ICD re-implantation, and 32 HCM patients referred for a first-time ICD placement during the same period. The 5-year-SCD risk was assessed for suitable patients using the recommended ESC calculator. Results: The first-time group had a higher 5-year-SCD risk than those referred for ICD re-implantation: 7.50 (IQR 5.98−10.46) vs. 4.88 (IQR 3.42−7.25), p < 0.05. Out of the patients with an initial calculated risk below 4%, the risk increased in 22% of cases, reaching the 4−6% range. In 78% of patients, the risk remained stable and low. In 31% of patients with an initial calculated SCD risk ≥ 6%, the risk decreased over time to below 6%, and in 14% of the cases, below 4%. Conclusions: SCD risk in HCM patients is usually stable or gets lower. Our data suggest it is important to re-evaluate the risk profile for patients with HCM when ICD re-implantation is considered.

19.
EuroIntervention ; 18(5): e417-e427, 2022 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-35321860

RESUMEN

BACKGROUND: Morbidly obese (MO) patients are increasingly undergoing transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) for severe aortic stenosis (AS). However, the best therapeutic strategy for these patients remains a matter for debate. AIMS: Our aim was to compare the periprocedural and mid-term outcomes in MO patients undergoing TAVR versus SAVR. METHODS: A multicentre retrospective study including consecutive MO patients (body mass index ≥40 kg/m2, or ≥35 kg/m2 with obesity-related comorbidities) from 18 centres undergoing either TAVR (n=860) or biological SAVR (n=696) for severe AS was performed. Propensity score matching resulted in 362 pairs. RESULTS: After matching, periprocedural complications, including blood transfusion (14.1% versus 48.1%; p<0.001), stage 2-3 acute kidney injury (3.99% versus 10.1%; p=0.002), hospital-acquired pneumonia (1.7% versus 5.8%; p=0.005) and access site infection (1.5% versus 5.5%; p=0.013), were more common in the SAVR group, as was moderate to severe patient-prosthesis mismatch (PPM; 9.9% versus 39.4%; p<0.001). TAVR patients more frequently required permanent pacemaker implantation (14.4% versus 5.6%; p<0.001) and had higher rates of ≥moderate residual aortic regurgitation (3.3% versus 0%; p=0.001). SAVR was an independent predictor of moderate to severe PPM (hazard ratio [HR] 1.80, 95% confidence interval [CI]: 1.25-2.59; p=0.002), while TAVR was not. In-hospital mortality was not different between groups (3.9% for TAVR versus 6.1% for SAVR; p=0.171). Two-year outcomes (including all-cause and cardiovascular mortality, and readmissions) were similar in both groups (log-rank p>0.05 for all comparisons). Predictors of all-cause 2-year mortality differed between the groups; moderate to severe PPM was a predictor following SAVR (HR 1.78, 95% CI: 1.10-2.88; p=0.018) but not following TAVR (p=0.737). CONCLUSIONS: SAVR and TAVR offer similar mid-term outcomes in MO patients with severe AS, however, TAVR offers some advantages in terms of periprocedural morbidity.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Obesidad Mórbida , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Obesidad Mórbida/complicaciones , Obesidad Mórbida/cirugía , Puntaje de Propensión , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...